Puzzle:Blackrock Aux Generators: Difference between revisions

From Stalburg Wiki
Jump to navigation Jump to search
m (Fixed the infobox to display properly.)
m (Edited type to be consistent with Puzzle Portal)
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{Puzzle_infobox
{{Puzzle_infobox
|name=Blackrock NPP Auxiliary Generators
|name=Blackrock Aux Generators
|map=npp
|map=npp
|types=Electricity, Generators
|types=Electical Power
|connections=None}}
|connections=None
|video=[https://www.youtube.com/watch?v=Yzu9XqzIsqU&feature=youtu.be YouTube]}}


<!-- Some pictures in article are missing as I can't play Infra to get the screenshots right now, so I've added some comments on where I'm planning to put them -->
<!-- Some pictures in article are missing as I can't play Infra to get the screenshots right now, so I've added some comments on where I'm planning to put them -->
Line 13: Line 14:
In order to restore the power all the generators must be turned on and synchronised to the grid. This can take a bit of trial and error as the synchroscopes are a bit tricky to align.
In order to restore the power all the generators must be turned on and synchronised to the grid. This can take a bit of trial and error as the synchroscopes are a bit tricky to align.


<!-- Insert picture of generators and buttons here -->
* Go down to the three generators and press the three buttons next to them.
* Go down to the three generators and press the three buttons next to them.
<!-- Insert picture of syncroscope here -->
<!--Insert picture of generators and buttons here-->
 
* Enter the control room overlooking them and manipulate each synchroscope with the two buttons next to them to get the needle stopped on the "In sync" line.
* Enter the control room overlooking them and manipulate each synchroscope with the two buttons next to them to get the needle stopped on the "In sync" line.
<!-- Insert picture of breaker button here -->
<!--Insert picture of syncroscope here-->
 
* Press the "Breaker" button next to the syncroscope.
* Press the "Breaker" button next to the syncroscope.
<!--Insert picture of breaker button here-->


If the needle is not correctly aligned or is moving, then the generator will stop when the breaker button is pushed. To restart the generator, press the button next to the generator again.
If the needle is not correctly aligned or is moving, then the generator will stop when the breaker button is pushed. To restart the generator, press the button next to the generator again.
[[Category:Puzzles]]

Latest revision as of 19:41, 1 August 2023

Blackrock Aux Generators
Puzzle Blackrock Aux Generators.png
General
Map npp
Type(s) Electical Power
Connections None
Video YouTube




After finding the first set of auxiliary generators flooded, the second set must be activated to turn on the power to gain access to the reactor and shut it down safely.

Solution[edit source]

In order to restore the power all the generators must be turned on and synchronised to the grid. This can take a bit of trial and error as the synchroscopes are a bit tricky to align.

  • Go down to the three generators and press the three buttons next to them.
  • Enter the control room overlooking them and manipulate each synchroscope with the two buttons next to them to get the needle stopped on the "In sync" line.
  • Press the "Breaker" button next to the syncroscope.

If the needle is not correctly aligned or is moving, then the generator will stop when the breaker button is pushed. To restart the generator, press the button next to the generator again.